• There is a solution to the earthquake.
Muş State Hospital

Muş State Hospital

Muş State Hospital is a hospital project undertaken by the Ministry of Health. Design, production and assembly of earthquake isolators that will form the seismic isolation system of the structure with reinforced concrete carrier system, TİS Technological Isolator Systems A.Ş. undertook. Production of TDP Earthquake Isolators Tis Technological Isolator Systems Inc. completed by. Information about the isolation system and isolators is given below.

The name of the manufactured device is

TİS Double Pendulum (TDP)

Project year 

2022

Total production custom

454

Displacement capacity of the isolators 

± 700 mm

Vertical load capacities of the isolators 

9300 /11300 /17600 /21900 /28400 kn